GENERAL DESCRIPTION:
The KDM variable area flow meter is
ideal for difficult applications requiring
high pressure operation or low pressure
loss. Its all metal, armored design is
available in stainless steel, PTFE clad
stainless steel, or Hastelloy C4.
In standard configuration, the KDM is a
purely mechanical meter. However,
electronic limit switches or an analog
flow transmitter may be added if so
desired. Switches and analog outputs are
available which operate in an intrinsically
safe mode and may be used with
explosive gases in intrinsically safe
installations.
The indicator translates the linear motion
of the float into an indication via a direct
magnetic coupling.
Specifications
 |
Accuracy
Metal Versions: ± 1.6% F.S.
PTFE Version: ± 2.5% F.S.
Fittings: ANSI Flanges
150 lb or 300 lb RF
Wetted Parts
Standard: 316-Ti SS
(Viton seal in
NPT versions)
Optional: PTFE clad SS
or Hastelloy C4
Damping System: Sapphire
Operating Temperature
Ambient: – 10 to 140 °F
Medium
No Options: – 110 to 390 °F
With Options: – see table
PTFE Clad: – 110 to 160 °F
High temperature versions on
request
Maximum Pressure
NPT Thread: 580 PSIG
Flanged: Per ANSI B16.5
High pressure units on request
|
Electrical Characteristics
Switches (optional)
Standard
Type: Proximity, 3-wire
Power: 10-30 VDC
Output: PNP, 100mA Max.
Intrinsically Safe
Type: Proximity
Output: NAMUR
Rating: EEx ia IIC T6
Analog Output (optional)
Type: 2-wire 4–20 mA
Input (Vcc): 12.7 to 30 VDC
Max. Load (Ω): Vcc-12 V/0.02 A
Resolution: + 0.5% F.S.
Repeatability: + 0.1% F.S.
Rating: EEx ia ll C T6
EEx ib ll C T6
(applies to
intrinsically safe
version only)
Housing: NEMA 4
Counter: 6-Digit LED
resettable
(M9 indicator only)
Optional Steam Jacket
Fittings:
ANSI Flange
NPT
|
 |
Meter Selection:
The KDM flow meter series can be
calibrated to provide direct reading
scales for a variety of media. To do a
custom calibration, We require
information on media density, viscosity, the
operating temperature and the operating
pressure.
It is required that option -D, the damping
mechanism, be added for all
gas applications whose downstream
pressure is less than 7 PSIG. This is
necessary to prevent unstable operation of
the float. Addition of the damping
mechanism increases the meter’s pressure
loss to 4.3 PSI.
Once an appropriate range has been
selected, refer to the Ordering Table on the
next page and assemble a part number.
KDM Flow Ranges

Operating Temperature with Options,
Non-Hazardous Location Service

Ordering Information

Dimensions
KDM-M9

KDM Meter Tube with Steam Jacket
 |
KDM Dimensions

|
|