DOM POSITIVE DISPLACEMENT FLOWMETER
DOM POSITIVE DISPLACEMENT FLOWMETER
   DOM POSITIVE DISPLACEMENT FLOWMETER
DOM POSITIVE DISPLACEMENT FLOWMETER

Special Features:

  • Low, Medium and High Flow Series
  • Flow Ranges From 0.13-9.5 GPH
  • Through 40-660 GPM
  • Line Sizes 1/8" Through 4"
  • Aluminum, Stainless Steel and Ductile Iron Bodies
  • Optional High-Viscosity Rotors on Some Models
  • For Use with a Wide Range of Fuels, Hydraulic Oils. Chemicals and Other Viscous Media
  • Electronics Packages Include Analog and Frequency Outputs, Mechanical
  • or LCD Totalizers and Batch Controllers
  • Bi-directional Flow Capability and Optional Quadrature Output
Low Flow Series Flow Ranges
DOM POSITIVE DISPLACEMENT FLOWMETER

Special Features:

  • Low Flow Series Flow Ranges 0.13-9.5 GPH Through 4-145 GPH
  • Line Sizes 1/8" Through 3/8"
  • Aluminum or Stainless Steel Bodies
  • Pressure ratings to 5800 PSIG
  • Liquid Viscosity to 500,000 cPs
  • Accuracy ±1% of Reading
  • Electronics Packages Include Pulse Output and LCD Ratemeter/Totalizer or Batch Controller
  • Bi-directional Flow Capability
General Description

The DOM series positive displacement flowmeter is the preferred choice for measuring viscous liquids such as lubricating/hydraulic oils, diesel fuels, chemicals, solvents, resins and pastes. The DOM Series employs the oval gear principle. Two oval shaped gears inside the meter will rotate when system pressure forces liquid through the flowmeter. These precision machined gears allow only a very precise volume of liquid to pass through the meter with each rotation. Permanent magnets mounted in the gears are used to detect the rotational speed of the gear which is directly proportional to flowrate. The output provided is a variable frequency pulse which can be used directly to measure and totalize flow or is used as an input to optional direct-mounted LCD ratemeter/totalizers or batch controllers.

The oval gear design very precisely measures liquid flow over a very wide viscosity range. Low flow series meters are available with aluminum or stainless steel bodies which are chemically resistant to a wide variety of liquids.

Specifications

Available Ranges: 0.13-9.5 through 4-145 GPH
Line Sizes: 1/8" through 3/8"
Liquid Types: Clean, viscous liquids

Liquid Viscosity Range
Standard: 0.3 cPs to 1000 cPs With Hi-Vis. Rotors:500,000 cPs
Accuracy: ±1.0% of reading
Repeatability: ±0.03% of reading
Filtration Req: 70 micron/200 mesh

Oper. Temp. Range
Pulse Output: -4°F to +250°F
LCD Displays: -4°F to +180°F
LCD Displays w/
Cooling Fin: -4° to +250°F

Wetted Materials
Body: Aluminum or 316L stainless steel
Gears: 316L stainless steel
Seals: Buna-N, EPDM, FFKM or teflon coated FFKM depending on model
Bearing: Ceramic

Maximum Pressure
Aluminum Body: 220 PSIG
316L Stainless Body: 500 PSIG (1500 PSI Opt.)

Hi-Pressure Stainless
Body: 5,800 PSIG
Pressure Drop: See Table

Electrical Specifications

Output H0, Standard Pulse
Description: Combined output with one reed switch pulser and one NPN Hall Effect pulser
Reed Switch: Max. 30 VDC, 200 mA
Hall Sensor: 3-wire, NPN open collector, 5-24 VDC 20 mA Max.
Electrical Connection: DIN 43650 Plug
Electrical Protection:
NEMA 4X/IP 67

Output D0, Quadrature Pulse
Description: Dual Hall Effect NPN pulsers phase offset 90°
Hall Sensors: 3-wire, NPN open collector, 5-24 VDC 20 mA Max.
Electrical Connection: DIN 43650 PLug
Electrical Protection: NEMA 4X/IP 65

Output Z1, Battery Powered Dual Totalizer
Display: LCD 2-line, resettable and nonresettable total
Battery: 3.6 V Lithium
External Power: 8-24 VDC
Output: Amplified pulse NPN or PNP selectable

Programmable Features
Lockout code, measuring units, pulse scale factor, totalizer reset
Electrical Connection: Cable Gland
Electrical Protection: NEMA 4X, IP67

Output Z3 Battery Powered Ratemeter/Totalizer
Display: LCD single line; toggles between rate, resettable and non -resettable total
Battery: 3.6 V Lithium
External Power: 8-24 VDC or 4-20 mA loop powered
Output: Scalable pulse and 4-20 mA flow rate output
Switches: NPN or PNP programmable setpoint

Programmable Features
Lockout code, measuring units, pulse scale factor, totalizer reset, alarm setpoints
Electrical Connection: 1/2" NPT
Electrical Protection: NEMA 4X, IP67

Output B1 Programmable Batch Controller
Display: LCD single line; toggles between batch total and grand total
External Power: 12-24 VDC @ 50 mA
Control Switches: 2-NPN Open collector, 2-stage with programmable prewarn

Programmable Features
Lockout code, measuring units, batch amount, Max. batch limit, prewarn setpoint,
Other Features: Remote start, stop and batch reset
Electrical Connection: 1/2" NPT
Electrical Protection: NEMA 4X, IP67

Ordering Information

DOM POSITIVE DISPLACEMENT FLOWMETER

DOM POSITIVE DISPLACEMENT FLOWMETER

Medium Flow Series Flow Ranges
DOM POSITIVE DISPLACEMENT FLOWMETER

Special Features:

  • Medium Flow Series Flow Ranges 0.26-10.6 GPM Through 9-150 GPM
  • Line Sizes 1/2" Through 2"
  • Aluminum or Stainless Steel Bodies
  • Pressure ratings to 5800 PSIG
  • Liquid Viscosity to 1,000,000 cPs
  • Accuracy ±0.5% of Reading
  • Electronics Packages Include Pulse Output and LCD Ratemeter/Totalizer or Batch Controller
  • All Mechanical Totalizing Display Available
General Description

The DOM series positive displacement flowmeter is the preferred choice for measuring viscous liquids such as lubricating/hydraulic oils, diesel fuels, chemicals, solvents, resins and pastes.

The DOM Series employs the oval gear principle. Two oval shaped gears inside the meter will rotate when system pressure forces liquid through the flowmeter. These precision machined gears allow only a very precise volume of liquid to pass through the meter with each rotation. Permanent magnets mounted in the gears are used to detect the rotational speed of the gear which is directly proportional to flowrate. The output provided is a variable frequency pulse which can be used directly to measure and totalize flow or is used as an input to optional direct-mounted LCD ratemeter/totalizers or batch controllers. An all mechanical totalizing display is available as an option. The mechanical totalizing displays have a resettable and nonresettable counter. The oval gear design very precisely measures liquid flow over a very wide viscosity range.

Specifications

Available Ranges: 0.26-10.6 through 9-150 GPM
Line Sizes: 1/2" through 2"
Liquid Types: Clean, viscous liquids

Liquid Viscosity Range
Standard: 0.3 cPs to 1000 cPs With Hi-Vis. Rotors:1,000,000 cPs
Accuracy: ±0.5% of reading
Repeatability: ±0.03% of reading

Oper. Temp. Range
Pulse Output & Mech. Totalizer:-4°F to +250°F
LCD Displays: -4°F to +180°F
LCD Displays w/
Cooling Fin: -4° to +250°F
Filtration Req: 150 micron/100 mesh

Wetted Materials
Body: Aluminum or 316L stainless steel
Gears: Aluminum for aluminum bodies (316L SS optional), and 316L SS for stainless steel bodies
Seals: Buna-N, EPDM, FFKM or teflon coated FFKM depending on model

Bearing:
Alum. Meters: Hardened steel
SS Meters: Ceramic
Pressure Drop: See Table

Electrical Specifications

Output H0, Standard Pulse
Description: Combined output with one reed switch pulser and one NPN Hall Effect pulser
Reed Switch: Max. 30 VDC, 200 mA
Hall Sensor: 3-wire, NPN open collector, 5-24 VDC 20 mA Max.
Electrical Connection: ½" NPT
Electrical Protection:NEMA 4X/IP 67

Output D0, Quadrature Pulse
Description: Dual Hall Effect NPN pulsers phase offset 90°
Hall Sensors: 3-wire, NPN open collector, 5-24 VDC 20 mA Max.
Electrical Connection: ½" NPT
Electrical Protection: NEMA 4X/IP 65

Output Z1, Battery Powered Dual Totalizer
Display: LCD 2-line, resettable and nonresettable total
Battery: 3.6 V Lithium
External Power: 8-24 VDC
Output: Amplified pulse NPN or PNP selectable

Programmable Features
Lockout code, measuring units, pulse scale factor, totalizer reset
Electrical Connection: Cable Gland
Electrical Protection: NEMA 4X, IP67

Output Z3 Battery Powered Ratemeter/Totalizer
Display: LCD single line; toggles between rate, resettable and non -resettable total
Battery: 3.6 V Lithium
External Power: 8-24 VDC or 4-20 mA loop powered
Output: Scalable and 4-20 mA flow rate output
Switches: NPN or PNP programmable setpoint

Programmable Features
Lockout code, measuring units, pulse scale factor, totalizer reset, alarm setpoints
Electrical Connection: 1/2" NPT
Electrical Protection: NEMA 4X, IP67

Output B1 Programmable Batch Controller
Display: LCD single line; toggles between batch total and grand total
External Power: 12-24 VDC @ 50 mA
Control Switches: 2-NPN Open collector, 2-stage with programmable prewarn

Programmable Features
Lockout code, measuring units, batch amount, Max. batch limit, prewarn setpoint,
Other Features: Remote start, stop and batch reset
Electrical Connection: 1/2" NPT
Electrical Protection: NEMA 4X, IP67

DOM POSITIVE DISPLACEMENT FLOWMETER

Ordering Information

DOM POSITIVE DISPLACEMENT FLOWMETER

DOM POSITIVE DISPLACEMENT FLOWMETER

High Flow Series Flow Ranges
DOM POSITIVE DISPLACEMENT FLOWMETER

Special Features:

  • High Flow Series Flow Ranges 10-200 GPM Through 40-660 GPM
  • Line Sizes 3" and 4"
  • Aluminum or Ductile Iron Bodies
  • Pressure ratings to 180 PSIG
  • Liquid Viscosity to 1,000,000 cPs
  • Accuracy ±0.5% of Reading
  • Electronics Packages Include Pulse Output and LCD Ratemeter/Totalizer or Batch Controller
  • All Mechanical Totalizing Display Available
General Description

The DOM series positive displacement flowmeter is the preferred choice for measuring viscous liquids such as lubricating/hydraulic oils, diesel fuels, resins and pastes.

The DOM Series employs the oval gear principle. Two oval shaped gears inside the meter will rotate when system pressure forces liquid through the flowmeter. These precision machined gears allow only a very precise volume of liquid to pass through the meter with each rotation. Permanent magnets mounted in the gears are used to detect the rotational speed of the gear which is directly proportional to flowrate. The output provided is a variable frequency pulse which can be used directly to measure and totalize flow or is used as an input to optional direct-mounted LCD ratemeter/totalizers or batch controllers. An all mechanical totalizing display is available as an option. The mechanical totalizing displays have a resettable and nonresettable counter.

The oval gear design very precisely measures liquid flow over a very wide viscosity range.

Specifications

Available Ranges: 10-200 through 40-660 GPM
Line Sizes: 3" and 4"
Liquid Types: Clean, viscous liquids Liquid Viscosity Range
Standard: 0.3 cPs to 1000 cPs
With Hi-Vis. Rotors:1,000,000 cPs
Accuracy: ±0.5% of reading
Repeatability: ±0.03% of reading

Oper. Temp. Range
Pulse Output & Mech. Totalizer:-4°F to +250°F
LCD Displays: -4°F to +180°F
LCD Displays w/
Cooling Fin: -4° to +250°F
Filtration Req: 150 micron/100 mesh

Wetted Materials
Body: Aluminum or ductile iron
Gears: Aluminum
Seals: Buna-N, EPDM,
FFKM or teflon coated FFKM depending on model
Bearing: Hardened steel

Maximum Pressure
3 inch meters: 180 PSIG
4 inch meters: 150 PSIG
Pressure Drop: See Table

Electrical Specifications

Output H0, Standard Pulse
Description: Combined output with one reed switch pulser and one NPN Hall Effect pulser
Reed Switch: Max. 30 VDC, 200 mA
Hall Sensor: 3-wire, NPN open collector, 5-24 VDC 20 mA Max.
Electrical Connection: ½" NPT
Electrical Protection:NEMA 4X/IP 67 Output D0, Quadrature Pulse
Description: Dual Hall Effect NPN pulsers phase offset 90°
Hall Sensors: 3-wire, NPN open collector, 5-24 VDC 20 mA Max.
Electrical Connection: ½" NPT
Electrical Protection:NEMA 4X/IP 65

Output Z1, Battery Powered Dual Totalizer
Display: LCD 2-line, resettable and nonresettable total
Battery: 3.6 V Lithium
External Power: 8-24 VDC
Output: Amplified pulse NPN or PNP selectable

Programmable Features
Lockout code, measuring units, pulse scale factor, totalizer reset
Electrical Connection: Cable Gland
Electrical Protection: NEMA 4X, IP67

Output Z3 Battery Powered Ratemeter/Totalizer
Display: LCD single line; toggles between rate, resettable and non -resettable total
Battery: 3.6 V Lithium
External Power: 8-24 VDC or 4-20 mA loop powered
Output: Scalable pulse and 4-20 mA flow rate output
Switches: NPN or PNP programmable setpoint

Programmable Features
Lockout code, measuring units, pulse scale factor, totalizer reset, alarm setpoints
Electrical Connection: 1/2" NPT
Electrical Protection: NEMA 4X, IP67

Output B1 Programmable Batch Controller
Display: LCD single line; toggles between batch total and grand total
External Power: 12-24 VDC @ 50 mA
Control Switches: 2-NPN Open collector, 2-stage with programmable prewarn

Programmable Features
Lockout code, measuring units, batch amount, Max. batch limit, prewarn setpoint,
Other Features: Remote start, stop and batch reset
Electrical Connection: 1/2" NPT
Electrical Protection: NEMA 4X, IP67

Ordering Information

DOM POSITIVE DISPLACEMENT FLOWMETER


Copyright 2006 Flow Network Acworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352
Email Sales@Flow-Network.com Website:
www.flow-network.com