GENERAL DESCRIPTION:
The KSK plastic flowmeters/ flow switches operate on the basis of the well known variable area principle. The medium flows upward through a conically widening plastic measuring tube. The float is lifted by the flowing medium and indicates the instantaneous flow rate on the scale attached to the flowmeter. The KSK series is all plastic with bodies made of nylon Polysulfone or PVDF to handle aggressive media.
For the control of flow setpoints, a bistable switch can be provided for the instrument. Reed contacts or transistor switches are available and can be used to monitor and alarm on an upset flow condition. The transistor switch has an LED on the contact housing to indicate switching status.
Measuring Scales
Measuring scales are available for water
and air. Compressed air scales are
available in SCFM, calibrated for direct
readings at operating pressures from
zero to 145 PSIG. The compressed air
scale table shows the available ranges
and calibration pressures for each meter
size.
Transistor Switch

Specifications
Accuracy: ±4% full scale
Flow Media: air or water and other
liquids
Mounting: vertical, flow up
Max. Media Temperature:
PVDF: 250°F
Trogamid: 140°F
Polysulfone: 140°F w/ PVC Fittings
180°F w/ Polypro, brass &
SS fittings
Max. Pressure: 145 PSIG
Materials
Measuring Tube: Polysulfone, Trogamid-T
or PVDF
Float: PVDF
O-Rings: EPDM
Connection
with Capnut: per ordering code
|
Switch Specifications
NPN Transistor: Hall-Sensor, bistable
NPN open collector
Operating Voltage: 9-24 VDC
Operating Current: Max.100 mA
Ambient Temp: 130°F max.
Hysteresis: <0.24
Output Signal: LED lights w/ flow
above setpoint
Reed Switch: SPST N/O or N/C
based on order code
Electrical Ratings: Max. 130 VAC
10 W / 10 VA, 0.5A
Ambient Temp: Max. 130°F
Protection: NEMA 4X/IP65 |
Ordering Information
Compressed Air Scale Ranges @ Specified Outlet Pressure (NOTE: Air units available only with Polysulfone (KSK-2...) measuring tube)

Order Numbers for Standard Types

Dimensions


|