Output S300/S30D, Adjustable Relay
Power Supply: 24 VDC ±20%
Switch Type
S300: SPDT relay, Max.
1 amp @ 30 VDC
S30D: PNP out 24 VDC with
N/O and N/C outputs
Switch Adjustment: Via external
potentiometer
Electrical Connection
S300: Micro-DC, 5-pin male
S30D: Micro-DC, 4-pin male
Electrical Protection: NEMA 4X/IP 65
Output F300/F390, PNP Frequency
Power Supply: 24 VDC ±20%
Output: PNP open collector,
200 mA Max.
Frequency Range
F300: 0–500 Hz
F390: User specified, factory set
0–50 Hz to 0–1000 Hz
Electrical
Connection: Micro-DC, 4-pin male
Electrical Protection: NEMA 4X/IP 65
Output L343, L443 Analog
Power Supply: 24 VDC ±20%
Output: 4–20 mA, 3-wire
Max. Load: 500Ω
Electrical Connection
L343: Micro-DC, 4-pin, male
L443: DIN 43650 Plug
Electrical Protection: NEMA 4X/IP 65
|
Output C34N, C34P, C30M, and C30R Compact Electronics
Power Supply: 24 VDC ±20%
Output
C34N: 4–20 mA, 3-wire and
1-NPN open collector
C34P: 4–20 mA, 3-wire and
1-PNP open collector
C30M: 2-NPN open collector
switches
C30R: 2-PNP open collector
switches
Max. Loop Load: 500Ω
Switch Rating: 300 mA
Programming: Switch setpoint, reset
point, switch logic,
4–20 mA span & zero,
dampening & lockout
code via 2-button
keypad
Electrical
Connection: Micro-DC 5-pin, male
Electrical Protection: NEMA 4X/IP 65
Integral Totalizer, E14R, E34R, E94R
Power Supply
Requirement: 24 VDC ±20%, 150 mA
Display Type: Backlit LCD, 2-line flowrate and total (8 digits) with
user-selectable units
Analog Output: 4–20 mA, 3-wire, 500Ω Max. loop load
Relays: 2x SPDT, Max. 250 VAC/5 Amp/1000 VA, assignable to switch on rate
or total
Functions: Totalizer reset, peak/valley indication, adjustable relay setpoints,
indicator language (7 available), measuring units
Electrical
Connection: Pigtail cable
Electrical Protection: NEMA 4X/IP 65
Integral Batch Controller, G14R, G34R, G94R
Power Supply
Requirement: 24 VDC ±20%, 150 mA
Display Type: Backlit LCD, 2-line flowrate and total (8 digits) with
user-selectable units
Analog Output: 4-20 mA, 3-wire, 500Ω Max. loop load
Relays: 2x SPDT, Max. 250 VAC/5 Amp/1000 VA, relay 1 assignable to switch
on flowrate, total or batch prewarn; relay 2 assignable to batch total
Functions: Totalizer reset, peak/valley indication, adjustable relay setpoints,
indicator language (7 available)
Electrical
Connection: Pigtail cable
Electrical Protection: NEMA 4X/IP 65 |