MIK Compact Magneto-Inductive Flowmeter
MIK Compact Magneto-Inductive Flowmeter
    MIK Compact Magneto-Inductive Flowmeter
MIK Compact Magneto-Inductive Flowmeter

Special Features:

  • Flow Ranges from 0.013–0.26 GPM through 9-180 GPM
  • For Use with a Wide Variety of Conductive Liquids, Acids, and Caustics
  • Magneto-Inductive Technology with No Moving Parts
  • Ryton Body with Stainless Steel Electrodes or PVDF Body with Hastelloy C Electrodes
  • Electronics Packages include Frequency or Current Outputs, Adjustable Switches and Integral Totalizers or Batch Controller
  • Economically Priced
GENERAL DESCRIPTION:

The MIK series magneto-inductive flowmeter is the perfect solution for measuring the flow of conductive liquids in applications where the reliability and low pressure loss of a magmeter is desired at an economical price compared to higher end models. The MIK measures flow using the magneto-inductive principle. According to Faraday’s law of magnetic induction, current is induced into a conductor as it moves through a magnetic field.

The amount of current induced is directly proportional to the velocity of the moving conductor. In the case of the MIK, a conductive liquid passing through the meter body acts as the conductor. The meter body contains a set of electromagnetic coils that generate the magnetic field. Electrodes mounted in the meter body collect the current whose magnitude is proportional to flowrate.

The MIK is all solid state and has no moving parts to wear, making it very reliable. Viscous and dirty liquids are measured with no accuracy degredation. The wetted materials for the flow body are either Ryton with 316L stainless steel electrodes or PVDF with Hastelloy C electrodes. A variety of fitting styles and materials are available, including PVC, PVDF, polypropylene and stainless steel. A wide variety of electronics packages are available, including frequency or current outputs, adjustable flow switches and integrated totalizers or batch controllers. The versatility of the MIK truly makes it a great value at an economical price.

General Specifications
Available Ranges: 0.013–0.26 through 9–180 GPM water
Liquid Types: Conductive liquids with conductivity >30 μS/cm
Accuracy: ±2.0% of full scale
Repeatability: ±1% of full scale
Straight Pipe Requirement: 3X Diameter upstream and 2X downstream
Oper. Temp. Range: 32–176°F (140°F Max. with PVC fittings)
Maximum Pressure: 145 PSIG @ 70°F
Max. Pressure Drop: 3.6 PSI @ 100% rated flow
Wetted Materials Sensor Housing: Ryton or PVDF depending on model
Electrodes: 316L St. steel or Hastelloy C4 depending on model
Seals: Buna-N, FKM or FFKM depending on model
Fittings: See “Ordering Information”
Electrical Specifications
Output S300/S30D, Adjustable Relay
Power Supply: 24 VDC ±20%
Switch Type
S300: SPDT relay, Max. 1 amp @ 30 VDC
S30D: PNP out 24 VDC with N/O and N/C outputs
Switch Adjustment: Via external potentiometer
Electrical Connection
S300: Micro-DC, 5-pin male
S30D: Micro-DC, 4-pin male
Electrical Protection: NEMA 4X/IP 65
Output F300/F390, PNP Frequency
Power Supply: 24 VDC ±20%
Output: PNP open collector, 200 mA Max.
Frequency Range
F300: 0–500 Hz
F390: User specified, factory set 0–50 Hz to 0–1000 Hz
Electrical Connection: Micro-DC, 4-pin male
Electrical Protection: NEMA 4X/IP 65
Output L343, L443 Analog
Power Supply: 24 VDC ±20%
Output: 4–20 mA, 3-wire
Max. Load: 500Ω
Electrical Connection
L343: Micro-DC, 4-pin, male
L443: DIN 43650 Plug
Electrical Protection: NEMA 4X/IP 65

Output C34N, C34P, C30M, and C30R Compact Electronics
Power Supply: 24 VDC ±20%
Output
C34N: 4–20 mA, 3-wire and 1-NPN open collector
C34P: 4–20 mA, 3-wire and 1-PNP open collector
C30M: 2-NPN open collector switches
C30R: 2-PNP open collector switches
Max. Loop Load: 500Ω
Switch Rating: 300 mA
Programming: Switch setpoint, reset point, switch logic, 4–20 mA span & zero, dampening & lockout code via 2-button keypad
Electrical Connection: Micro-DC 5-pin, male
Electrical Protection: NEMA 4X/IP 65
Integral Totalizer, E14R, E34R, E94R
Power Supply Requirement: 24 VDC ±20%, 150 mA
Display Type: Backlit LCD, 2-line flowrate and total (8 digits) with user-selectable units
Analog Output: 4–20 mA, 3-wire, 500Ω Max. loop load
Relays: 2x SPDT, Max. 250 VAC/5 Amp/1000 VA, assignable to switch on rate or total
Functions: Totalizer reset, peak/valley indication, adjustable relay setpoints, indicator language (7 available), measuring units
Electrical Connection: Pigtail cable
Electrical Protection: NEMA 4X/IP 65
Integral Batch Controller, G14R, G34R, G94R
Power Supply Requirement: 24 VDC ±20%, 150 mA
Display Type: Backlit LCD, 2-line flowrate and total (8 digits) with user-selectable units
Analog Output: 4-20 mA, 3-wire, 500Ω Max. loop load
Relays: 2x SPDT, Max. 250 VAC/5 Amp/1000 VA, relay 1 assignable to switch
on flowrate, total or batch prewarn; relay 2 assignable to batch total
Functions: Totalizer reset, peak/valley indication, adjustable relay setpoints, indicator language (7 available)
Electrical Connection: Pigtail cable
Electrical Protection: NEMA 4X/IP 65

Estimated Weight

(see ordering information for flow range codes and electronics option codes)
MIK Compact Magneto-Inductive Flowmeter
Total Weight = Sensor Weight + Electronics Weight

Ordering Information

(Example: MIK-5NAU4MS300)
MIK Compact Magneto-Inductive Flowmeter

Dimensions (Inches)

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

MIK Compact Magneto-Inductive Flowmeter

 


Copyright 2006 Flow Network 5065 Vail Drive Acworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352
Email Sales@Flow-Network.com Website:
www.flow-network.com