DUK COMPACT ULTRASONIC FLOWMETER
DUK COMPACT ULTRASONIC FLOWMETER
   DUK COMPACT ULTRASONIC FLOWMETER
DUK COMPACT ULTRASONIC FLOWMETER

Special Features:

  • Measuring Ranges: 0.02-5 GPM to 0.6-160 GPM
  • Accuracy: ±1.5 % of F.S.
  • Turndown Ratio: 250:1
  • Pmax: 230 PSI; Tmax: 248° F
  • Connections: ½ to 3 G or NPT
  • Material: Brass or 1.4408 Stainless Steel
  • Outputs: Analog, Frequency, Switching, Compact Electronics with Digital Displays, Batching and Totalizing Electronics
DUK COMPACT ULTRASONIC FLOWMETER

DUK COMPACT ULTRASONIC FLOWMETER

General Description

The DUK flow meters are used for measuring, monitoring, metering, and batching of low viscosity fluids. The devices work on the principle of run time difference. Ultrasonic waves in the media are influenced by the rate of flow. Two sensors mounted opposite one another in the pipeline function simultaneously as transmitter and receiver of the ultrasonic signals.

If there is no flow, the run times of both signals are identical. If the media is flowing, then the run time of the signal against the flow is longer than the signal with flow. The run time difference, which is determined by a microprocessor, is proportional to the rate of flow.

DUK COMPACT ULTRASONIC FLOWMETER

The devices can be equipped with a switching output, a frequency output or an analog output. In addition, a compact electronic can be selected that features a digital display, a switching output, and an analog output.

The device series is rounded off by an optionally available batching or totalizing electronic. The meter electronic indicates the momentary flow rate in the first line of the display and the partial or total flow in the second line.

A batching electronic controls simple filling tasks and similarly measures flow rates, total amounts and filling amounts. The analog output and two relay outputs can be used for further processing of the signals.

Specifications
Measuring principle: Ultrasonic
Range: See Table
Media: Liquids with max. 1 % solid
Viscosity: Max. 3 cSt
Accuracy: ±1.5 % of F.S.
Repeatability: ±0.5 % of F.S.
Mounting Position: Universal: flow in direction of the arrow (horizontal: electronic on top or below)
Straight Piping: 10 x pipe diameter in/out

Media Temperature: - 4 to 194 °F - 4 to 248 °F (High temperature version)
Ambient Temperature: - 4 to 158 °F
Response Time: Approx. 0.5...1 s (depending on electronic version)
Max Pressure: 230 PSI
Pressure Loss: Max. 2.2 PSI at F.S.
Protection: IP 65 / NEMA 4
Wetted Parts
Sensor Housing: Brass or 1.4408 Stainless Steel
Sensors: PEEK
Seal: NBR (other on request)

DUK COMPACT ULTRASONIC FLOWMETER
Electrical Specifications

DUK-...S300, DUK-...S30D
Display: Bicolor LED for switch status
Switching Output (..S300): SPDT relay, max. 1 A / 30 VDC
Switching Output (..S30D):Active 24 VDC, N/C and N/O
Switch Point: 10 to 90 % of f.s. in 10 %-steps configurable by the customer using a rotary switch
Power Supply: 24 VDC ± 20 %
Power Consumption: 30 mA
Electrical Oonnection: Plug M 12, 5-pin

DUK-...F300, DUK-…F390
Pulse Output: PNP, Open Collector, max. 200 mA
Frequency at F.S.: 500 Hz (…F300) 50 to 1000 Hz (…F390) user specified
Power Supply: 24 VDC ± 20 %
Power Consumption: 25 mA
Electrical Connection: Plug M 12, 5-pin

DUK-...L343
Analog Output: 4-20 mA, 3-wire
Load: Max. 500 Ω
Power supply: 24 VDC ± 20 %
Power Consumption: Max. 45 mA
Electrical Connection: Plug M 12x1

DUK-...L443 (Required with optional AUF-3000)
Output: 4 - 20 mA, 3-wire
Load: Max. 500 Ω
Power Supply: 24 VDC ± 20 %
Power Consumption: Max. 45 mA
Electrical Connection: Plug DIN 43650

DUK-...C3xx (Compact Electronic)
Display: 3-digit LED
Analog Output : 4-20 mA adjustable (only DUK-...C34x)
Load: Max. 500 Ω
Switching Output: 1(2) semiconductor PNP or NPN
Contact Function: N/C-N/O-frequency programmable (approx. 1400 Hz at F.S., uncalibrated)
Settings: Via 2 buttons
Power Supply: 24 VDC ± 20 %
Power Consumption: Approx. 100 mA
Electrical Connection: Plug M 12x1

DUK-...Ex4R (Totalizing Electronic)
Display: LCD, 2 x 8 digit, illuminated rate, total and grand total, units selectable
Analog Output: 4-20 mA adjustable
Load: Max. 500 Ω
Switching Output: 2 relays, max. 250 V/5 A /1000 VA
Settings: Via 4 buttons
Functions: Reset, MIN/MAX memory, flow rate, total and grand total, language
Power Supply: 24 VDC ± 20 %, 3-wire
Power Consumption: Approx. 170 mA
Electrical Connection: Cable connection or M12 plug

DUK-...Gx4R (Batching Electronic)
Display: LCD, 2 x 8 digit, illuminated batching, total and grand total, units selectable
Analog Output: 4-20 mA adjustable
Load: Max. 500 Ω
Switching Output: 2 relays, max. 250 V / 5 A / 1000 VA
Settings: Via 4 buttons
Functions: Batching (relay S2), start, stop, reset, fine batching,correction amount, flow switch, total quantity, language
Power Supply: 24 VDC ± 20 %, 3-wire
Power Consumption: Approx. 170 mA
Electrical Connection: Cable connection or M12 plug

DUK with ADI Electronic
Display: Bar graph and 3.5-digit digital combination display; batch system
Analog Output: 4-20 mA, 0 to 10 V
Switching Output: 2 x relays / SPDT max. 115 / 230 VAC, 5A resistive load max. 30 VDC / 5 A or 2 Open-Collector 5 - 50 VDC, Itotal. = 50 mA
Settings: Via 3 buttons
Power Supply: 230 /115 VAC, 24 VDC
Electrical Connection: Terminal block via cable gland

Electrical Connection

DUK COMPACT ULTRASONIC FLOWMETER

DUK COMPACT ULTRASONIC FLOWMETER

Ordering Information