3000 Series Air Flow Monitors (vent-captors)
The 3000 series of Air Flow Switches and
Air Flow Transmitters provides the simplest, most reliable
means of detecting air flow in a wide variety of industrial
and commercial applications. Unlike mechanical flow switches
or sail switches, the vent-captor series does not rely on
moving parts. Air flow is detected using the “Calorimetric
Principle” which is further discussed on our home page
under the “Leak Detection using the calorimetric principle”
article.
The sensor will not be damaged by excessive
air flow as often occurs with mechanical switches. It can
also detect much lower flow than any mechanical device. Air
flow rates as low as 0-3 ft. per second are easily realized.
However the units are also capable of rates as high as 150
ft. per second or more.
AC or DC versions are available.
Outputs can be a solid state switch with
adjustable set point, or a 4-20 MA transmitter with adjustable
zero and span, allowing the user to set the unit in the field
to their particular flow rate.
No moving parts means no wear, no sticking,
no broken paddles, no maintenance, and years of dependable
performance.
|
Applications include:
- Sensing air flow in ducts
- Monitoring cooling airflow to electronic cabinets or enclosures
- Monitoring compressed air or detecting leaks in pressurized
systems
- Air flow in fuel cells
- Detecting air filter conditions to allow replacement of clogged
filters
- Air flow in fume hoods
- Monitoring air flow rates to bubbler systems in Waste Water
treatment
These are just a few of the many applications for the vent-captor
air flow monitors. In addition they carry the CE mark, are resin
epoxy encapsulated for high resistance to shock and vibration.
MOST POPULAR MODELS ARE
FOR AC - MODEL 3201.51
Fail Safe Normally Open logic means you will get a signal with FLOW ABOVE SETPOINT.
Please specify whether your application is for 120V or 220V service.
If you prefer a signal for FLOW BELOW SETPOINT, please specify 3201.50
For applications involving pressure in excess of 25 PSI please specify the 3205.51
with stainless steel jacket and Union Nut .
FOR DC (24V) – MODEL 3202.03
Fail Safe Normally Open logic means you will get a signal with FLOW ABOVE SETPOINT.
If you prefer a signal for FLOW BELOW SETPOINT, please specify 3202.02
For pressures above 25 PSI please specify the 3205.03 with stainless steel jacket
and Union Nut.
<<<<<<< Please see DATA SHEETS (pdf ‘s) LOCATED TO THE LEFT for further information.
Call us today and let us help with your application for Air Flow
Monitoring.